試驗(yàn)室磁選管技術(shù)參數(shù)
Technical Parameter of laboratory Magneric Tube
XCGQ磁選管又名戴維斯分析管,用于礦山,冶金,地質(zhì)等實(shí)驗(yàn)室。是選礦過程中,用來測(cè)定磁性礦石中磁性成分的一種設(shè)備。本產(chǎn)品由原地礦部唯一指定企業(yè)生產(chǎn),執(zhí)行行業(yè)標(biāo)準(zhǔn)。
XCGQ磁選管式在C型電磁鐵的兩級(jí)端之間,裝有玻璃鋼作往復(fù)移動(dòng)和擺動(dòng)。被分選的試料在通過磁場(chǎng)區(qū)時(shí),磁性部分即附在管壁附近。非磁性部分在機(jī)械運(yùn)動(dòng)中被水沖刷而排出。
XCG(Q)S 50 Magnetic Tube or Davis Analyzing Tube is applicable in labs.of mine,metallurgical,geological and other industries.It is designed to determine magnetic content in strong magnertic mineral in the mineral processing operation. The product is produced by the only enterprise designated by the former Ministry of Geology and Mineral Mineral Resources,in compliance with the Industrial standards
Magnetic Tube is C Type electromagnet fitted with glass tube between pole ends to reciprocately move and swing.When the test materials to be separated pass therough magneric fields.the magnetic portion will be absorbed near the tube walls and the non-magneric portion will be washed down by water in the mechanical movement and discharged.. The product is produced by the only enterprise designated by the former Ministry of Geology and Mineral Mineral Resources,in compliance with the Industrial standards
型號(hào)Model | 單位 Uite | XCGQ 50 |
玻璃管直徑Tube Dia | mm | 50 |
振動(dòng)頻率Vibrating Freq | r/min | 70 |
兩磁及頭間隙 | mm | 52 |
給料粒度Feed size | mm | 0.5 |
磁場(chǎng)強(qiáng)度Intensity | GS | 2500(200KA/m)無級(jí)可調(diào) |
電壓Voltage | V | 50HZ 220交流 |
激磁功率Exciting power | VA | 500 |
配套輔機(jī)Supply equipment | taiwan | 激磁電源1臺(tái) |
外形Overall dimensions | mm | 1000/800/500 |
重量Weighe | kg | 200 |
本設(shè)備適用于各種產(chǎn)品的低溫速凍試驗(yàn),如化工,物理,醫(yī)藥,儀器,儀表,電器,海洋生物等,疫苗血清的低溫存放,微生物的研究和培養(yǎng),藥品的試驗(yàn)和儲(chǔ)存,建筑材料的低溫檢測(cè)等,本儀器由名牌進(jìn)口壓縮機(jī)、冷凝器、過濾器、毛細(xì)管、蒸發(fā)器恒溫槽數(shù)顯儀表數(shù)碼控溫系統(tǒng)等組成。本機(jī)制冷速度快噪音小,使用可靠方面。
二、技術(shù)參數(shù):
本儀器容積:115L
內(nèi)部尺寸:470*425*490mm
最低溫度: -40℃
控溫精度(均勻性):±2℃
電源:AC220V、50Hz
環(huán)境溫度:0-23℃.
相對(duì)濕度:不大于75%
三、結(jié)構(gòu)特點(diǎn):
該儀器選用上開門,加厚保溫層,對(duì)低溫保持效果好,實(shí)驗(yàn)方便,恒溫槽采用防腐性較強(qiáng)的合金板,外用優(yōu)質(zhì)鋼板制作,中間充聚胺脂保溫材料。
四、注意事項(xiàng):
1、儀器不允許在有潮濕及腐蝕性氣體的環(huán)境中存放與使用。第一次使用(長(zhǎng)時(shí)間未用情況下)本機(jī)必須工作2小時(shí)后方能做檢測(cè),以免第一次使用數(shù)值不準(zhǔn)確。 2、由于某些原因斷電或停電,就立即關(guān)掉電源開關(guān),若需要新啟動(dòng),必需間隔30分鐘以上方能開機(jī)使用,以免急速開機(jī)燒毀壓縮機(jī)。
3、本儀器適用于實(shí)驗(yàn)室化驗(yàn)用。
4、嚴(yán)禁在不使用時(shí)長(zhǎng)時(shí)間運(yùn)行。
5、搬運(yùn)時(shí),傾斜角不得大于45℃,以免造成壓縮機(jī)或系統(tǒng)故障,使用時(shí),拆去所有包裝,冷凍箱背面大于50cm,兩側(cè)離墻大于15cm,冷凍箱應(yīng)放在通風(fēng)干燥處,避免在陽光下工作,遠(yuǎn)離水池、熱源、磁場(chǎng)和各種揮發(fā)性、腐蝕性物質(zhì)。
6、必須使用獨(dú)立插座,插座和電線的電流容量,應(yīng)不小于10A,插座必須可靠接地。
7、使用電源為交流單相50HZ,電壓220--242V,電壓不穩(wěn),請(qǐng)加裝輸入功率5倍以上穩(wěn)壓器,使用時(shí)需用穩(wěn)壓器調(diào)節(jié):220V 50Hz 15A。本儀器必須接地
五、冷凍須知:
1、放置試樣時(shí),試樣與試樣、試樣與冷凍箱內(nèi)膽要留一定的間隙,以保證冷氣流動(dòng),降溫均勻。
2、在試驗(yàn)濕度較高物件和易失水份的物件,請(qǐng)用密封膠好的食品袋或保鮮紙包好放入,以防水份跑出,在工作室內(nèi)結(jié)霜,影響制冷。
3、嚴(yán)禁在冷凍箱內(nèi)存放易揮發(fā)、燃燒的氣體、液體,如強(qiáng)堿、強(qiáng)酸、汽油、酒精等物品。
4、一次放入的試樣不能多,否則會(huì)使壓縮機(jī)長(zhǎng)時(shí)間不停機(jī)而且箱內(nèi)溫度下降緩慢,反而達(dá)不到要求。
5、工作完畢后,切斷電源,取出已冷凍樣品,打開冷凍箱門讓其自然升溫,化霜層融化,將水放出用軟布吸干擦凈。
六.使用方法:
1、在使用速凍箱之前,仔細(xì)閱讀使用說明書。
2、開機(jī)前檢查: A)速凍箱必須有獨(dú)立的電源插座及可靠接地。電壓允許波動(dòng)范圍220-240V,頻率49-51HZ。 B)在接通外電源之前,必須首先檢查面板上開關(guān),保證面板上開關(guān)處于關(guān)機(jī)狀態(tài)。
3、開機(jī):插上電源,同時(shí)將面板上電源開關(guān)置開機(jī)狀態(tài),此時(shí)顯示表頭顯示出箱體溫度值。電腦溫控器設(shè)定的延時(shí)啟動(dòng)時(shí)間過后壓機(jī)開始運(yùn)轉(zhuǎn)。
4、工作:待溫度達(dá)到要求后,迅速,逐漸將儲(chǔ)存物品均勻放入箱內(nèi)。
5、停機(jī):使用完畢后,需要停機(jī)時(shí),必須首先將面板上電源開關(guān)置關(guān)機(jī)狀態(tài)(顯示器滅)然后切斷外接電源。
七、維修與保養(yǎng):
1、冷凍箱在使用中應(yīng)每做一次試驗(yàn)應(yīng)清洗一鎰,清洗時(shí)切斷電源取出物品,將污物水份擦干。
2、禁用沸水、酸制劑、化學(xué)稀釋劑等。
3、清洗后,應(yīng)揩抹干凈。
4、清洗門封條時(shí),請(qǐng)使用淡肥皂水,小心擦洗。
5、清洗外殼時(shí),可用水或少量中性洗凈劑清洗,注意不要使用電源線和下部接線漫水,而受潮漏電。
八、一般故障及排除方法:
1、指示亮不亮,開關(guān)開后無儀表顯示,檢查電源及插頭。
2、指示燈亮,壓縮機(jī)不正常工作,只有嗡嗡聲。電壓低, 加裝輸入5倍以上穩(wěn)壓器。
3、壓縮機(jī)啟動(dòng)后,在1分鐘內(nèi)又停機(jī),等幾分鐘后,又重復(fù)起動(dòng),如此反復(fù),按2維修。
4、壓縮機(jī)正常,降溫慢:①開門次數(shù)多或門未關(guān)緊。②物品放入過多,且放置不當(dāng)。③冷凍箱結(jié)霜。
5、噪聲過大:①冷凍箱放置不平穩(wěn)。②冷凍箱昆固件松動(dòng)。③制冷箱與壓縮機(jī)有接觸。
九、下列現(xiàn)象并非故障,請(qǐng)勿擔(dān)心:
1. 速凍箱工作時(shí)和停止工作后一段時(shí)間內(nèi),管道內(nèi)制冷劑循環(huán)流動(dòng),發(fā)出(咕嚕咕嚕)的流水聲。
2. 壓縮機(jī)工作時(shí),表面溫度可能達(dá)到70℃~80℃。
3. 壓縮機(jī)啟動(dòng).停止時(shí),開關(guān)部件會(huì)發(fā)出輕微的撞擊聲。
4. 多雨潮濕季節(jié),箱體表面可能結(jié)霜,用干布擦去即可。
5. 速凍箱襯口內(nèi)側(cè),為超低溫下應(yīng)力釋放區(qū),在高低溫交變情況下會(huì)有輕微裂痕,屬于正,F(xiàn)象,可正常使用。
性能特點(diǎn) 完全符合JJG59-2007 《活塞式壓力計(jì)》、 JJG99-2006 《砝碼》國(guó)家計(jì)量檢定規(guī)程,運(yùn)用我廠 50 年核心技術(shù)推出的活塞式壓力計(jì)。 活塞和活塞筒采用高強(qiáng)度,高硬度和低溫度線脹系數(shù)的合金鋼、碳化鎢等材料制成,溫度膨脹系數(shù)小、變形量小,因而保證活塞有效面積周期變化率較小 從而保證活塞壓力計(jì)有極高的靈敏度 。活塞和活塞筒經(jīng)精工研磨,其圓度誤差和間隙極小 ,工作介質(zhì)采用低黏度的癸二酸脂,因而極大的提高活塞轉(zhuǎn)動(dòng)延續(xù)時(shí)間,也就相應(yīng)減小活塞下降速度,提高活塞鑒別力。 出于檢定工作的需要,使活塞有效面積相對(duì)較小,因此砝碼總質(zhì)量相對(duì)較輕,節(jié)省勞動(dòng)強(qiáng)度。 采用托盤直接加載,避免了附加垂直力,降低了砝碼重心, 相應(yīng)減小砝碼側(cè)向附加誤差。使活塞轉(zhuǎn)動(dòng)更平穩(wěn)。活塞工作位置采用位移傳感器監(jiān)測(cè),具有靈敏、醒目、準(zhǔn)確的優(yōu)點(diǎn)。砝碼已經(jīng)進(jìn)行壓力形變系數(shù)和當(dāng)?shù)刂亓铀俣鹊男拚?/span>送檢時(shí)只需送檢活塞測(cè)量系統(tǒng),體積小、重量輕。
活塞壓力計(jì)參數(shù):
型號(hào) |
| YS-6 | YS-60 | YS-250 | YS-600 |
| |||||
參 數(shù) | 單位 | 測(cè)量范圍 | |||||||||
0.04~0.6MPa | 0.1~6MPa | 0.5~25MPa | 1~60MPa |
| |||||||
標(biāo)稱上限 | MPa | 0.6 | 6 | 25 | 60 |
| |||||
標(biāo)稱下限 | MPa | 0.04 | 0.1 | 0.5 | 1 |
| |||||
測(cè)量上限 | MPa | 0.6 | 6 | 60 | 60 |
| |||||
測(cè)量下限 | MPa | 0.04 | 0.1 | 0.5 | 1 |
| |||||
活塞公稱面積 | CM 2 | 1 | 1 | 0.5 | 0.1 |
| |||||
底盤及活塞 | 產(chǎn)生的壓力 | MPa | 0.04 | 0.5 | 0.5 | 1 |
|
| |||
產(chǎn)生的壓力 | MPa | 0.001:0.05 | 0.1;0.5 | 0.5:2.5 | 1;5 |
|
| ||||
數(shù)量 | 個(gè) | 6;10 | 4;11 | 4;9 | 4;11 |
|
| ||||
接口 |
| M20 × 1.5 | M20×1.5 | M20 × 1.5 | M20×1.5 |
| |||||
重量 | Kg | 35 | 65 | 75 | 95 |
| |||||
工作液體 |
| 變壓器油或變壓器油與煤油的混合油 20 ℃ 時(shí)運(yùn)動(dòng)粘度 9 ~ 12 厘池酸值不大于 0.05 毫克 KOH/ 克 | 癸二酸酯(癸二酸二異戊酯或癸二酸二異辛酯)20 時(shí)運(yùn)動(dòng)粘度 20 ~ 25 厘池,酸值不大于 0.05毫克 KOH/ 克 |
詳情請(qǐng)登錄:www.101yb.com進(jìn)行了解 咨詢電話: 2016-7-6
廣州實(shí)驗(yàn)室設(shè)備生產(chǎn)廠家|實(shí)驗(yàn)室邊臺(tái)|實(shí)驗(yàn)室家具生產(chǎn)廠家
Ø設(shè)備型號(hào)
YT.E-01微型設(shè)備(過濾面積0.005m2),過濾動(dòng)力:蠕動(dòng)泵提供
YT.E-02微型設(shè)備(過濾面積0.005m2),過濾動(dòng)力:(衛(wèi)生級(jí))離心泵提供,如圖1
YT.E-03小型設(shè)備(過濾面積0.24m2),過濾動(dòng)力:(衛(wèi)生級(jí))離心泵提供,如圖2
YT.E-04小型設(shè)備(過濾面積0.36m2),過濾動(dòng)力:(衛(wèi)生級(jí))離心泵提供,如圖2
YT.E-05小型設(shè)備(過濾面積0.44m2),過濾動(dòng)力:(衛(wèi)生級(jí))離心泵提供,如圖2
陶瓷膜設(shè)備可根據(jù)特殊要求進(jìn)行定制,如衛(wèi)生級(jí)、封閉空間、防爆等,定制設(shè)備也可選擇不同的過濾面積,即50cm2*N、0.2m2*N、0.36 m2*N、0.44m2*N,其中N=1, 3,7,19,37,或更多。
Ø核心元件:進(jìn)口陶瓷膜,材質(zhì):99瓷氧化鋁
Ø設(shè)備材質(zhì):不銹鋼(蠕動(dòng)泵提供動(dòng)力的YT.E-01除外)
Ø化學(xué)性能:耐強(qiáng)酸、強(qiáng)堿、腐蝕
Ø工作壓力:0.05MPa—0.50Mpa
Ø工作溫度:< 100℃
設(shè)備循環(huán)料液體積
型號(hào) | -01 | -02 | -03 | -04 | -05 |
料槽體積 | —— | ||||
最小料液量 |
膜管平均孔徑規(guī)格
陶瓷膜孔徑 | ||||||||||||||||||||||
微濾/μm | 超濾
設(shè)備特點(diǎn) ²料液即可進(jìn)行,且設(shè)備可放大能適應(yīng)處理大量料液 ²微濾設(shè)備配備反沖裝置 ²膜管規(guī)格齊全,系列膜管可實(shí)現(xiàn)互換 ²溫度可控,料槽帶夾套可加熱或冷卻 ²清洗簡(jiǎn)單,再生能力強(qiáng)
產(chǎn)品特點(diǎn)1.客觀:本裝置在我國(guó)最常用的“容積法檢定”或“稱重法”基礎(chǔ)上,采用攝像機(jī)代替人眼來讀取水表指針,符合國(guó)家計(jì)量檢定規(guī)程JJG162-85等的水表讀數(shù)要求,自動(dòng)識(shí)別精度達(dá)到水表最小分值的1/3;是一致公靠的自動(dòng)化改造方案;經(jīng)國(guó)內(nèi)眾多地區(qū)使用效果十分理想。2.自動(dòng)化程度高:安裝水表之后,除了要求水表編號(hào)輸入到計(jì)算機(jī)外,就不再需人工操作,點(diǎn)擊“開始檢定”圖標(biāo),裝置自動(dòng)依次完成公稱、分界、最小流量的檢定。3.軟件功能強(qiáng):裝置配備的計(jì)算機(jī)檢定軟件,自動(dòng)按規(guī)程計(jì)算并得出檢定結(jié)論,可保存全部水表檢定數(shù)據(jù),具有檢定記錄查詢、修正、統(tǒng)計(jì)、打印等完善的數(shù)據(jù)庫功能。4.技術(shù)含量高:該裝置采用圖像視覺技術(shù),利用人工智能來識(shí)別被檢水表表盤讀數(shù),使得操作方便,穩(wěn)定,提高檢定效率,避免人為誤差,性價(jià)比較高。5.適用性廣:幾乎能檢定國(guó)內(nèi)所有指針式水表,非常適合對(duì)我國(guó)大多數(shù)新舊水表臺(tái)進(jìn)行升級(jí)改造:值得廣大計(jì)量檢定機(jī)構(gòu)、自來水公司和水表生產(chǎn)廠家采用。 產(chǎn)品規(guī)格檢 測(cè) 范 圍:15-50mm口徑的干、濕式水表檢測(cè)水表數(shù)量:1-20只信 號(hào) 輸 入:1-20路視頻信號(hào); 4-8路水位測(cè)量信號(hào)控 制 輸 出:4-12路大功率繼電器輸出(可用于控制電磁閥門等)自動(dòng)測(cè)量精度:圖像識(shí)別誤差:1/4分格 水位測(cè)量誤差:0.01% 數(shù) 據(jù) 處 理:自動(dòng)按規(guī)程計(jì)算并得出檢定結(jié)論,可保存水表檢定數(shù)據(jù),具有檢定記錄查詢、修正、統(tǒng)計(jì)、打印等數(shù)據(jù)庫功能攝像系統(tǒng)配置:攝像機(jī)、圖象采集卡、臺(tái)式計(jì)算機(jī)、打印機(jī) 說明: 產(chǎn)品簡(jiǎn)介: 本機(jī)可測(cè)試橡、塑料、皮革、金屬、尼龍線、織物、紙及航空、包裝、建筑、石化、電工、車輛…..等等材料之拉伸、壓縮、彎折、剪力、粘接力、剝離、撕裂…等等試驗(yàn),為質(zhì)量管理、進(jìn)料檢驗(yàn)、物性試驗(yàn)、力學(xué)研究、材料開發(fā)之基本設(shè)備。 主要技術(shù)參數(shù): 容量選擇: 100, 200, 500 N; 1, 2, 5, 10, 20 kN 單位切換: kgf , gf, Ton, Ibf, N, kN, or 自定義 荷重分解度: 1/50,000 荷重精度: ± 0.5% 最大行程(不含夾具): 1150mm 寬度: 400 mm 測(cè)試速度: 0.0001~999 mm/min 位移分解度: 0.01 mm 數(shù)據(jù)采樣頻率: 16 次/秒 顯示裝置: 顯示器(可顯示及打印試驗(yàn)次數(shù),測(cè)試值,值,斷裂值等) 馬 達(dá): AC 伺服馬達(dá) 體 積:-主機(jī)114×63×240cm(W×D×H) 重 量:-主機(jī) 384kg(不含夾具) 電 源: 1∮,220V, 15A 或指定 雅仕檢測(cè)設(shè)備有限公司聯(lián)系人: 周生電話: 0512-55530996移動(dòng)電話:13092657216 實(shí)際演示和可視化能力移動(dòng)床實(shí)驗(yàn)在工程建筑物模型周圍的流動(dòng)腐蝕和沉淀的實(shí)驗(yàn)研究曲折的水管線路的特征借助Ahlborn 技術(shù)的二維空間的可視化流動(dòng)邊界層引力演示管流的速度分布液壓模擬可壓縮流土木工程模型測(cè)試 描述 實(shí)驗(yàn)臺(tái)用深藍(lán)色 (BS0105)玻璃纖維鑄成,并用加強(qiáng)塑料和鋼來增強(qiáng)耐久度。它的構(gòu)造分三個(gè)區(qū):入口箱,工作區(qū)和排放蓄水池。區(qū)段由法蘭連接并作為一個(gè)整體直接從工廠發(fā)放。在排放池中有一個(gè)下落的、松緊程度可調(diào)的上突出堰,帶逆流沙陷阱。入口箱以一塊穿孔的隔板為特色,這塊板能使流動(dòng)在實(shí)驗(yàn)臺(tái)的寬度上平均地分布。 可移除的玻璃片,一邊為藍(lán)色, 另一邊為白色, 當(dāng)可視化流動(dòng)實(shí)驗(yàn)進(jìn)行時(shí)用來覆蓋沙床。兩根可調(diào)的鋁軌裝配在實(shí)驗(yàn)臺(tái)的頂端。這些擴(kuò)展了工作區(qū)的全長(zhǎng),其中一根鋁軌上標(biāo)有定位標(biāo)尺。所提供的深度標(biāo)尺被用于測(cè)量水位和繪制實(shí)驗(yàn)期間沙床延伸的等高線。它提供有不銹鋼鉤和尖,且?guī)в杏纬呖潭纫詼y(cè)定水位。 標(biāo)尺被設(shè)計(jì)為裝在儀器的架子上,可以架設(shè)在工作區(qū)域的任何點(diǎn)上方。主傳送器 (縱向移動(dòng)) 具有一個(gè)鎖定裝置和游標(biāo),與儀器鋁軌刻度協(xié)同操作。次傳送器 (橫向移動(dòng)) 在由主傳送器提供的軌道上操作。這里也有一個(gè)橫向刻度尺和鎖定裝置。裝置的正確使用在隨實(shí)驗(yàn)臺(tái)供應(yīng)的手冊(cè)中加以詳細(xì)描述。 水流是由離心泵驅(qū)動(dòng),其所用原料具有很好的抗腐蝕性,還用于管道工程包括電力操作的流體調(diào)節(jié)閥。 一個(gè) GRP(玻璃鋼) 模制帶有泵、控制閥、硬質(zhì)管道工程管和在線流量計(jì)。這套集合含有軟管連接到實(shí)驗(yàn)臺(tái)。馬達(dá)起動(dòng)器和數(shù)字標(biāo)尺讀出器被裝在一張外形漂亮的臺(tái)子上,里面包含有所需的電纜線。 實(shí)驗(yàn)臺(tái)可根據(jù)需要的工作長(zhǎng)度選擇。 S2-2 M型: 工作長(zhǎng)度 2 米 S2-4 M型: 工作長(zhǎng)度 4 米 基本配件 為方便使用儀器,提供有各種模型和配件。 為配合儀器得到的結(jié)果,提供各種被證明有用的材料, 包括鋁塵罐, 注射器和聚乙烯管,顏料晶體,橡皮泥和海報(bào)漆的長(zhǎng)度。除此之外,還供應(yīng)下列各項(xiàng)物品: 橋墩模型;二個(gè)矩形的, 四個(gè)圓柱形的, 二張側(cè)繪圖和二個(gè)有圓頭的。 一個(gè)不對(duì)稱機(jī)翼形狀。 二個(gè)模型門指引者。 八張鋁隔板用于在一般測(cè)試中指示水流動(dòng)。 一套12個(gè) x 50 mm x 50 mm 鋁球座和六根長(zhǎng)125 mm,寬和高各 40 mm 的等角鋁管, 使實(shí)驗(yàn)員能夠建立附加的模型。 產(chǎn)品說明: |